TY - Generic T1 - Factors influencing groundwater inflows in a newly constructed cross-strike tunnel, eastern Massachusetts; 1, Lineaments and subsurface structures T2 - Abstracts with Programs - Geological Society of America Y1 - 1999 A1 - Curry, Patrick J. A1 - Hardcastle, Kenneth C. A1 - Stephen B Mabee A1 - Williams, Katherine W. KW - #StaffPubs KW - BEDROCK KW - eastern Massachusetts KW - fractures KW - geophysical surveys KW - ground water KW - Hydrogeology 21 KW - lineaments KW - massachusetts KW - metamorphic rocks KW - movement KW - New England KW - remote sensing KW - SLAR KW - strike KW - surveys KW - tectonics KW - tunnels KW - United States AB - Lineaments derived from three platforms; 1:250,000 Side-Looking Airborne Radar (SLAR) images, 1:58,000 Color Infrared (CIR) and 1:80,000 Black and White aerial photographs (BW), were compared to water bearing structures (n = 99) within a 9 km, 70 to 90 meter deep, east-west tunnel being constructed in eastern Massachusetts. Lineaments were drawn by three observers during two independent trials to produce 18 sets of lineaments (n = 9137) covering approximately 1,000 km (super 2) centered over the tunnel. All lineaments for each platform were compared. Three or more overlapping lineaments (azimuths within 5 degrees and within 1 mm at the scale of the imagery) define a single coincident lineament. This analysis generated three sets of coincident lineaments (n = 794), of these 37 cross the tunnel. Buffers were placed around the coincident lineaments at a distance of 1 mm from the center of the lineament at the scale of the platform (e.g. 250 m for the SLAR image). The Mann-Whitney U test was used to determine if the median flow from all tunnel structures which underlie the lineament buffer zones is significantly greater than that of all structures outside of the buffer zones. Results indicate that median flow (11,000 l/day) from structures located within the buffer zones of the BW are significantly greater at the 90% confidence level than the median flow (5,500 l/day) of structures located outside the buffer zones. No significant differences in flow were found for the other two platforms. Subsurface structures that parallel coincident lineaments (all platforms) and occur within the buffer zones have higher median flow (10,500 l/day) than those structures outside the buffer zones (6,600 l/day). However, this difference is significant at the 70% confidence level. These results suggest that, in some instances, a thorough lineament analysis can predict water-bearing subsurface structures in poorly exposed, glaciated, metamorphic terrain that has a high degree of suburban development. JF - Abstracts with Programs - Geological Society of America PB - Geological Society of America (GSA) : Boulder, CO, United States CY - United States VL - 31 SN - 00167592 IS - 77 N1 - Accession Number: 2001-037333; Conference Name: Geological Society of America, 1999 annual meeting; Denver, CO, United States; Conference Date: 19991025; Language: English; Coden: GAAPBC; Collation: 2; Collation: 347-348; Publication Types: Abstract Only; Serial; Conference document; Updated Code: 200111; Monograph Title: Geological Society of America, 1999 annual meeting; Monograph Author(s): Anonymous; Reviewed Item: Analytic JO - Abstracts with Programs - Geological Society of America ER - TY - Generic T1 - Factors influencing groundwater inflows in a newly constructed cross-strike tunnel, eastern Massachusetts; 3, Surface vs. subsurface fracture characteristics T2 - Abstracts with Programs - Geological Society of America Y1 - 1999 A1 - Stephen B Mabee A1 - Williams, Katherine W. A1 - Curry, Patrick J. A1 - Hardcastle, Kenneth C. KW - #StaffPubs KW - BEDROCK KW - controls KW - eastern Massachusetts KW - factors KW - fractures KW - ground water KW - Hydrogeology 21 KW - massachusetts KW - measurement KW - movement KW - New England KW - outcrops KW - spatial distribution KW - tunnels KW - United States AB - Major fracture sets (dip >45 degrees ), their geographic distributions (domains), and their characteristics (spacing, trace length, and planarity) were measured in surface outcrops and in a 9 km section of the tunnel (Curry et al., this volume) to determine how well fracture data collected at widely-spaced surface exposures can be extrapolated to a depth of 70 to 90 meters. For the surface fracture data set, fracture sets and domains were determined from 1513 measurements collected at 21 outcrops located within 3 km of the trace of the tunnel. Spacing, trace length, and planarity were determined from scanline measurements (n = 899). For the tunnel data set, 413 fracture measurements were made to determine major sets and domains and a smaller subset (n = 156) was used to estimate fracture characteristics.Five fracture sets (14, 38, 86, 117, and 171) were identified in the outcrops and seven sets (13, 29, 41, 62, 132, 159, and 175) in the tunnel. The 14 and 171 sets correspond well with the 13 and 175 sets in the tunnel. The 38 set observed at the surface includes parts of the 29 and 41 sets in the tunnel. The 86 set does occur in the tunnel but is undersampled because it is aligned with the tunnel. The 62 and 159 sets occur in the tunnel but are not seen at the surface. Although large areas are devoid of outcrops, comparison of surface and subsurface fracture domains indicates that only the 14 and 171 sets show a reasonable overlap with the 13 and 175 domains in the tunnel. These latter sets are the fractures generating most of the groundwater inflow into the tunnel. Median fracture spacing and trace lengths for the 13 and 175 sets in the tunnel are significantly wider and longer than the corresponding 14 and 171 sets at the surface. Fracture planarities showed no significant differences between any of the surface and subsurface fracture sets. JF - Abstracts with Programs - Geological Society of America PB - Geological Society of America (GSA) : Boulder, CO, United States CY - United States VL - 31 SN - 00167592 IS - 77 N1 - Accession Number: 2001-037340; Conference Name: Geological Society of America, 1999 annual meeting; Denver, CO, United States; Conference Date: 19991025; Language: English; Coden: GAAPBC; Collation: 1; Collation: 348; Publication Types: Abstract Only; Serial; Conference document; Updated Code: 200111; Monograph Title: Geological Society of America, 1999 annual meeting; Monograph Author(s): Anonymous; Reviewed Item: Analytic JO - Abstracts with Programs - Geological Society of America ER - TY - Generic T1 - Factors influencing groundwater inflows in a newly constructed cross-strike tunnel, eastern Massachusetts; 2, Fracture-supported coincident lineaments and subsurface structures T2 - Abstracts with Programs - Geological Society of America Y1 - 1999 A1 - Hardcastle, Kenneth C. A1 - Curry, Patrick J. A1 - Williams, Katherine W. A1 - Stephen B Mabee KW - #StaffPubs KW - BEDROCK KW - controls KW - eastern Massachusetts KW - factors KW - fractures KW - ground water KW - Hydrogeology 21 KW - imagery KW - lineaments KW - massachusetts KW - movement KW - New England KW - outcrops KW - Structural geology 16 KW - tectonics KW - tunnels KW - United States AB - As part of the evaluation of the ability of lineaments to map subsurface structures, the coincident lineaments which intersect the tunnel (Curry et al., this volume), were evaluated to isolate those lineaments considered to be "fracture-supported". By definition, fracture-supported coincident lineaments are those which parallel nearby surface fracture sets, mapped faults, lithologic contacts, and/or primary ductile structures; features which may be influential to subsurface groundwater flow. Of the 37 coincident lineaments delineated on the three scales of imagery studied, approximately 70% are considered to be fracture-supported: 9 of the 13 on the 1:58,000 scale images, 10 of 14 on the 1:80,000, and 8 of 10 on the 1:250,000. However, the general lack of surface exposure precludes high confidence in the assignment of fracture-supported status to most lineaments. Large areas devoid of outcrops necessitated extrapolation of regional, surface fracture patterns (domains) to help define some fracture-supported coincident lineaments. There are two occurrences where fracture-supported coincident lineaments from all three scales overlap and are parallel. One occurrence successfully maps the zone of greatest fracture density and highest groundwater inflow (>560 l/min). The other occurrence maps an area of high fracture density and significant subsurface flow (95 l/min). In addition, one other high flow zone (>190 l/min) is mapped by a fracture-supported coincident lineament from the 1:80,000 scale imagery. However, many subsurface fractures and flow zones (<75 l/min) are not mapped by the coincident lineaments regardless of whether or not they are fracture-supported. When considering all fracture-supported coincident lineaments and parallel subsurface structures, the median flow (13,600 l/day) for the mapped structures is greater than the unmapped structures (6,800 liters/day). However, this difference is only significant at the 60% confidence level.Although the tunnel sections with the greatest fracture density and highest groundwater inflows are successfully mapped by fracture supported coincident lineaments, not all water-bearing zones are delineated. JF - Abstracts with Programs - Geological Society of America PB - Geological Society of America (GSA) : Boulder, CO, United States CY - United States VL - 31 SN - 00167592 IS - 77 N1 - Accession Number: 2001-037344; Conference Name: Geological Society of America, 1999 annual meeting; Denver, CO, United States; Conference Date: 19991025; Language: English; Coden: GAAPBC; Collation: 1; Collation: 348; Publication Types: Abstract Only; Serial; Conference document; Updated Code: 200111; Monograph Title: Geological Society of America, 1999 annual meeting; Monograph Author(s): Anonymous; Reviewed Item: Analytic JO - Abstracts with Programs - Geological Society of America ER - TY - Generic T1 - Factors influencing groundwater inflows in a newly constructed cross-strike tunnel, eastern Massachusetts; 5, Geochemical interpretation of groundwater inflows T2 - Abstracts with Programs - Geological Society of America Y1 - 1999 A1 - Weaver, Rebecca A. A1 - Stephen B Mabee A1 - Williams, Katherine W. A1 - Curry, Patrick J. KW - #StaffPubs KW - anions KW - BEDROCK KW - cations KW - classification KW - discharge KW - eastern Massachusetts KW - fault zones KW - faults KW - geochemistry KW - ground water KW - hydraulic conductivity KW - hydrochemistry KW - Hydrogeology 21 KW - Isotope geochemistry 02D KW - isotope ratios KW - isotopes KW - massachusetts KW - movement KW - New England KW - nitrate ion KW - O-18/O-16 KW - oxygen KW - samples KW - stable isotopes KW - surface water KW - tunnels KW - United States AB - Samples of ground and surface waters in and above the tunnel (Curry et al., this volume) were collected to characterize the chemistry of groundwater discharging from fractures and faults. Forty-two water samples were collected: 32 along a transect of the tunnel and 10 from surface waters above the trace of the tunnel. All samples were analyzed for major anions and cations, and delta (super 18) O. Analysis of the anion/cation data indicated that these waters are dominated by sulfate+chloride and calcium+magnesium. However, five sub-classifications can be discerned based on the relative concentrations of ions in the samples. The five sub-classifications are Cl > HCO (sub 3) > SO (sub 4) > NO (sub 3) :Ca > Na+K > Mg (15 samples), Cl > HCO (sub 3) > SO (sub 4) > NO (sub 3) :Na+K > Ca > Mg (7 samples), Cl > HCO (sub 3) > SO (sub 4) > NO (sub 3) :Ca > Mg > Na+K (6 samples), Cl > SO (sub 4) > HCO (sub 3) > NO (sub 3) :Na+K > Ca > Mg (3 samples), and HCO (sub 3) > Cl > SO (sub 4) > NO (sub 3) :Ca > Na+K > Mg (2 samples). Results from statistical analyses indicate that alkalinity, calcium, sodium and potassium do vary as a function of bedrock type and that these differences are significant at the 95% confidence level.In addition, preliminary oxygen isotope data indicate that two large, discrete water producing fault zones located in the eastern part of the tunnel are isotopically enriched (average delta (super 18) O = -7.75) relative to other water producing features in the tunnel (average delta (super 18) O = -8.96). The delta (super 18) O values obtained from all surface water bodies located above the tunnel average -7.56 whereas those values in surface ponds immediately above the fault zones average -6.71. Nitrate levels also show elevated levels in two water producing fault zones (>10 mg/L for some samples) and may result from accidental contamination during sampling, the use of explosives at discrete locations in the tunnel, or from leaking septic systems. The results of the oxygen isotope and nitrate analyses also suggest that some of the fault zones in the tunnel may have a rapid and direct hydraulic connection to the surface. JF - Abstracts with Programs - Geological Society of America PB - Geological Society of America (GSA) : Boulder, CO, United States CY - United States VL - 31 SN - 00167592 IS - 77 N1 - Accession Number: 2001-037342; Conference Name: Geological Society of America, 1999 annual meeting; Denver, CO, United States; Conference Date: 19991025; Language: English; Coden: GAAPBC; Collation: 1; Collation: 348; Publication Types: Abstract Only; Serial; Conference document; Updated Code: 200111; Monograph Title: Geological Society of America, 1999 annual meeting; Monograph Author(s): Anonymous; Reviewed Item: Analytic JO - Abstracts with Programs - Geological Society of America ER -